305 North Second #180
Upland, CA 91786
909.982.7742
Hours of Operation
Monday Through Friday
6:30 a.m. to 5:00 p.m.
Key Design WebsitesThe HAV blower forces air through a specially designed HEPA Filter, filtering air to .3 microns, and entering the tank at a volume of 600 CFM. This air circulates through the headspace and exits through a specialty vent that does not restrict the exit air flow. Unlike other systems that pull air through the filters and actually have considerable filter bypass air entering the tank; it is virtually eliminated by this system. Due to the nature of the filters and design, new gasket material is in place every time you change out the filters. This maintains a very tight seal around all the components to eliminate air bypass.
The Pre-Filter is made of 100% Dacron fibers, 4 ply thick with a built in tacifier. This Pre-Filter will trap particulates down to 10 microns, much smaller then most electrostatic filters, taking the boulders out of the air and reducing the build up load on the HEPA. This Pre-Filter is over 1500 sq. inches, much larger then competitor filters and far more efficient.
With the design of this system, all blower contaminants are trapped in the HEPA. All blower motors are dirty components of any system and throw off particulates from the windings, bearings and armatures that can become part of your ingredient if not treated properly within the system. The HAV will not allow anything but the cleanest, purest air possible to enter the tank headspace.
Normal filter change out is once a year, although changing out the Pre-Filter more frequently can extend the HEPA filter life. Made up of all stainless steel construction, this HAV system will provide many years of service.